Build a rig that adds up.
Check spacing, thread handoffs, sensor coverage, image scale, and field of view before ordering another adapter.
Saved on this browser
No cloud sync. Avoid saving sensitive records on a shared browser.
Illustrative starting inputs. Replace them with your own measurements and evidence.
One train. Every connection visible.
1 spacing, connection, coverage, or missing-component checks need attention.
Optical order: telescope side → sensor
Ordered train- 1Spacer16.5 mm · M48x0.75 female → M42x0.75 male
- 2Filter drawer21 mm · M42x0.75 female → M42x0.75 male
- 3Camera flange to sensor17.5 mm · M42x0.75 female → Sensor
Before you act
- Use matching diameter, pitch, gender, and flange-reference conventions. Nominal thread labels do not verify engagement depth or clearance.
- Verify the reducer-specific working distance and filter correction with the manufacturer. A larger image circle does not guarantee good corner stars.
Rig bill of materials
| Spacer | 16.5 | M48x0.75 female | M42x0.75 male | User-entered; verify |
| Filter drawer | 21 | M42x0.75 female | M42x0.75 male | User-entered; verify |
| Camera flange to sensor | 17.5 | M42x0.75 female | Sensor | User-entered; verify |
Calculation notes & limitations
Effective focal length = telescope focal length × reducer or Barlow factor. Pixel scale = 206.265 × pixel size in micrometers ÷ focal length in millimeters.
Optional plane-parallel glass correction adds thickness × (1 − 1/refractive index) to the physical backfocus target. Apply only when the manufacturer reference excludes this correction.
Field angle = 2 × arctan(sensor dimension ÷ (2 × focal length)). Mechanical lengths are summed once; include the camera sensor flange distance as a train component.
The method is part of the tool.
Enter the exact focal length, reducer factor, sensor dimensions, and published sensor working distance for your equipment.
List the optical train in physical order, including every spacer and the camera sensor flange distance. Match thread pitch and gender, not just nominal diameter.
Compare summed mechanical distance with the target, apply any documented filter correction once, and report field of view and angular sampling separately.
Read the full methodologyEvidence before certainty.
Spacing and nominal thread agreement do not guarantee physical clearance, engagement depth, sensor illumination, or optical quality. Verify each manufacturer reference.
These are reference sources, not evidence that example records have been verified. Imported records retain the source links you provide.